Secure Computing SG570 Instrukcja Użytkownika Strona 256: Port Tunnels
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
Possible cause:
Windows network browsing broadcasts are not being transmitted
through the tunnel.
Solution:
Set up a WINS server and use it to have the remote hosts resolve names
to IP addresses.
Set up LMHOST files on remote hosts to resolve names to IP adresses.
Symptom:
Tunnel comes up but the application does not work across the tunnel.
Possible cause:
There may be a firewall device blocking IPSec packets.
The MTU of the IPSec interface may be too large.
The application uses broadcasts packets to work.
Solution:
Confirm that the problem is the VPN tunnel and not the application being
run. These are the steps you can try to find where the problem is (it is assumed that
a network to network VPN is being used):
Ping from your PC to the Internet IP address of the remote party (it assumed that the
remote party is configured to accept incoming pings)
Ping from your PC to the LAN IP address of the remote party.
Ping from your PC to a PC on the LAN behind the remote party that the tunnel has
been configured to combine.
If you cannot ping the Internet IP address of the remote party, either the remote party
is not online or your computer does not have its default gateway as the SnapGear
unit. If you can ping the Internet IP address of the remote party but not the LAN IP
address, then the remote party's LAN IP address or its default gateway has not been
configured properly. Also check your network configuration for any devices filtering
IPSec packets (protocol 50) and whether your Internet Service Provider is filtering
IPSec packets. If you can ping the LAN IP address of the remote party but not a host
on the remote network, then either the local and/or remote subnets of the tunnel
settings have been misconfigured or the remote host does not have its default
gateway as the remote party.
If you can ping across the tunnel, then check if the MTU of the IPSec interface is
allowing packets to go through. Reduce the MTU if large packets are not being sent
through the tunnel.
If the application is still not working across the tunnel, then the problem is with the
application. Check that the application uses IP and does not use broadcast packets
since these are not sent across the IPSec tunnels. You should contact the producer
of the application for support.
Port Tunnels
Port tunnels are point to point tunnels similar to regular VPNs, but only offer transport for
a TCP service from one end of the tunnel to the other. This allows you to “wrap” a TCP
service, such as telnet or mail retrieval (POP3), in an HTTP or SSL connection. Note that
a single port tunnel may transport a single TCP port only.
250
Virtual Private Networking
Plik PDF · ·
Pytania o Secure Computing SG570
Nie ma jeszcze pytań o tę instrukcję. Zadaj pierwsze.