Secure Computing SG550 Instrukcja Użytkownika Strona 296: Failed Upgrade
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
Appendix D – Recovering From a Failed Upgrade
292
Wait for the recovery procedure to complete and the SG unit to finish reprogramming.
Note
It takes a few minutes for your SG to finish reprogramming. After it has finished it reboots
automatically with its old configuration intact. If it is uncontactable after rebooting, hit the
Reset/Erase button twice within 2 seconds to restore factory default configuration, then
follow the instructions in the chapter entitled
Getting Started
to begin reconfiguration of
your unit.
Recovery using a BOOTP server
The following is a brief guide to performing a recovery boot when you are unable to
access either Netflash or a Windows PC on which to run it. More comprehensive
instructions are not given, as they vary depending on your operating system and server
software packages.
The recovery procedure involves network booting the unit using a BOOTP server with
access to a SG firmware image file, then upgrading the network as per a normal flash
upgrade to reprogram its flash to a usable state.
Note
To perform the recovery boot, you must have a firmware image for your SG unit. The
firmware that shipped with your unit is located in the
\firmware
directory on the SG CD.
The latest firmware for your SG unit can be obtained from SG customer support
Firmware files have the format
Model_Version_Date.sgu
or
Model_Version_Date_*.sgu
.
Log in to your PC with sufficient permissions to edit the server configuration files, and
stop and start the servers.
Place the firmware file in your BOOTP server’s path, e.g.:
/tftpboot/
Edit your BOOTP server configuration to contain an entry for the SG unit. Specify the
firmware file as the file to boot, e.g.:
filename "SG300_v2.1.3_20041213.sgu";
Plik PDF · ·
Pytania o Secure Computing SG550
Nie ma jeszcze pytań o tę instrukcję. Zadaj pierwsze.