Secure Computing SG550 Instrukcja Użytkownika Strona 68: Edit connection parameters

/ 297
Spis treści
Rozwiązywanie problemów
Network Setup
64
Ping Interval
is the time to wait in between sending each ping,
Failed Pings
is the
number of missed ping replies before this connection attempt is deemed to have
failed.
Click
Finish
.
Modify failover levels (primary, secondary, tertiary)
The second and final step of configured Internet failover is associating Internet
connections with and primary, secondary and optionally tertiary connection levels.
Recall that a connection level is one or more connections. These connections may be
marked as
Required
or
Enabled
. Internet connections that are marked
Disabled
are not
part of this connection level. A connection level is deemed to be up when all connections
marked
Required
at that level are up, and at least one connection (marked
Required
or
Enabled
) at that level is up.
On the
Network Setup
page, click the
Failover & H/A
tab, then
Modify Levels
. A table
is displayed listing each of the connections alongside a drop down box for each
connection level.
Note
If a connection is marked
<Always Up>
, you must edit its connection parameters as
described by the previous section before it can be associated with a connection level.

Plik PDF · ·

Drukuj

Drukuj dokument

Dzielenie się

Pytania o Secure Computing SG550

Nie ma jeszcze pytań o tę instrukcję. Zadaj pierwsze.

Zadaj pytanie

Odpowiadamy na podstawie instrukcji i wskazujemy stronę. Pytanie pojawi się w serwisie po sprawdzeniu.

Wszystkie pytania i odpowiedzi ›